Page 1050 - All Industrial Tool Supply | General Catalog
P. 1050

COUNTERS • Surface Roughness
         1048

                  Portable Surface Roughness Tester


                     Finally a user-friendly surface roughness
                     measurement instrument!         BeneFits:
                                                     •  This is it! A small, lightweight and extremely easy to use surface roughness measurement
                                                      instrument that lets you view surface roughness waveforms right on the color LCD screen.

                                                     Features:
                                                     •  Battery-powered portability scores when making surface roughness measurements on
                                                      the shop floor.
                                                     •  Intuitive 2.4" color graphic LCD display with backlight.
                                                     •  Simple key layout.
                                                     •  Advanced data storage capabilities with password protection - Up to 10 measurement
                                                      conditions and one measured profile can be stored in the internal memory.
                                                     •  Display interface supports 16 languages, which can be freely switched.
                                                     •  Stylus alarm warns you when the cumulative measurement distance exceeds a preset limit.
                                                     •  Displays assessed profiles and graphical data - In addition to calculation results, the Surftest
                                                      SJ-210 can display sectional calculation results and assessed profiles, load curves, and
                                                      amplitude distribution curves.
                                                     •  The drive unit can be separated from the display unit by using a cable, allowing more flexible
                                                      measurement - driver can be separated and reattached in one simple step.
                                                     •  Complies with the following standards: JIS (JIS-B0601-2001, JIS-B0601-1994, JIS B0601-1982),
                                                      VDA, ISO-1997 and ANSI












                                                         ShOwn with CaRRying CaSe





                                                                                     Optional Printer Available,
                                                                                     Please Call
                                                                                       MoDeL        oRDeR    PRice
                                                                                        #            #       eacH
       SiMPLe Key LayOut  ShOwn with OPtiOnaL PRinteR         ReaR PaneL             178-561-02A  57-016-291  $2,429.99
       SPecificaTionS:
       Model # ................................................................... SJ-210 (178-561-02A) 4mN Type  Calculation Result Display
       Measuring Range                                        Vertical Display ...........................1 parameter / 3 parameter / trace to measurements
       X Axis ....................................................................................................0.69" (17.5mm)  Horizontal Display ......................1 parameter / 4 parameter / trace to measurements
       Z Axis .................... 14,200 µin (-7,900µin ~ + 6,300µin) / 360µm (-200µm ~ + 160µm)     (Horizontal display is invertable)
       Range/Resolution ................................................ 14,170µin / .8µin (360µm / 0.02µm),  Printing Function ............................... Measurement conditions / Calculation results /
                4,000µin / .2µin (100µm / 0.006µm), 1000µin / .08µin (25µm / 0.002µm)     Calculation Results for each sampling length / Assessed profile /
       Measuring Speed                                                             Bearing area curve / Amplitude distribution curve /
       Measuring ...............................  0.01, 0.02, 0.03 in/s (0.25mm/s, 0.5mm/s, 0.75mm/s)     Environment setting information (Dedicated printer is required separately)
       Returning ...........................................................................................................1mm/s  External I/O .......USB I/F, Digimatic Output, Printer Output, RS-232C I/F, Foot SW I/F
       Measuring Force/Stylus Tip............................................................... 4mN / 5µmR 90°  Customization .........Desired parameters can be selected for calculation and display
       Skid Force ........................................................................................Less than 400mN  GO/ NG Judgment .................................... By max. value / 16% / Standard deviation
       Applicable Standards .......................JIS ’82 / JIS ’94 / JIS ’01 / ISO ’97 / ANSI / VDA  Functions
       Assessed Profiles .............................Primary profile / Roughness profile / DF profile /  Storage
                                             Roughness profile-Motif  Internal Memory ............... Measurement condition (10 sets), Measured profile (1 set)
       Evaluation Parameters ............ Ra, Rc, Ry, Rz, Rq, Rt, Rmax, Rp, Rv, R3z, Rsk, Rku,  Memory Card (Optional) ......500 measurement conditions, 10000 measured profiles,
             RPc, Rsm, Rz1max, S, HSC, RzJIS, Rppi, RΔa,RΔq, Rlr,Rmr, Rmr (c), RΔc, Rk,               500 display images
            Rpk, Rvk, Mr1, Mr2, A1, A2, Vo, Rpm, tp, Htp, R, Rx, AR, Possible Customize  Text File ................. (Measurement conditions / Measured profile / Assessed profile /
       Analysis Graphs..............................Bearing area curve / Amplitude distribution curve     Bearing area curve / Amplitude distribution curve)
       Filters ..................................................................................... Gaussian, 2CR75, PC75  Calibration ..................... Auto-calibration with the entry of numerical value / Average
       Cut Off Length                                                     calibration with multiple measurement is available (max. 5 times)
       λc ...................................................0.003", 0.01", 0.03", 0.1" (0.08, 0.25, 0.8, 2.5mm)  Power-Saving Function .....................................Auto-sleep off function (10 - 600 sec)
       λs .............................................................................................. 100, 300µin (2.5, 8µm)  Power Supply
       Sampling Length .............................0.003", 0.01", 0.03", .1" (0.08, 0.25, 0.8, 2.5mm)  Two-Way Power Supply ..........Battery (rechargeable Ni-MH battery) and AC adapter
       Number Of Sampling Lengths (×n) .................×1, ×2, ×3, ×4, ×5, ×6, ×7, ×8, ×9, ×10,  Charging Time ........................ About 4 hours (may vary due to ambient temperature)
       ............ arbitrary length 0.01 ~ .63" (.0001" interval) (0.3 ~ 16.0mm: 0.01mm interval)  Endurance ..............................About 1,000 measurements (differs slightly due to use
       LCD Dimensions                     1.45 x 1.93" (36.7 × 48.9mm)                            conditions / environment)
       Display Languages ...................Japanese, English, German, French, Italian, Spanish,  Display Unit Dimensions ...................2.05"W x 2.6"D x 6.3"H (52.1 × 65.8 × 160mm)
                      Portuguese, Korean, Traditional Chinese, Simplified Chinese,  Drive Unit Dimensions .............................4.5"W x 0.9"D x 1.02"H (115 × 23 × 26mm)
                            Czech, Polish, Hungarian, Turkish, Swedish, Dutch  Weight .............................................................................................................. 1.1 lbs.
   1045   1046   1047   1048   1049   1050   1051   1052   1053   1054   1055