Page 616 - Ceratizit Catalog
P. 616

The interface
   C11





                                                                The strong connection
                                    Gap
                                                                Unclamped module

                                                                ○ Gap between module and location face for axial clamping


                                         Gap





                                                                Clamped module

                                                                ○ Axial clamping with location face
                                                                ○ Connection without clearance, therefore highest stability











                                                                Clamping features
                                                                LX / GX / AX
                                   LX           GX
                                  4        4                    Active insert clamping

                                                                Screws 1, 2 and 3 are used to clamp the module. The insert
                                                                is self-clamping. The insert is clamped through the elastic
                                                                deformation of the module through the additional screw 4.
                       3
                    2                           AX
                                                   4
                        1






                                                                FX / SX
                                   FX           SX
                                                                Self-clamping inserts

                                                                Screws 1, 2 and 3 are used to clamp the module. The insert
                                                                is self-clamping.

                       3
                    2
                         1         GX          3 TC             GX / TC
      Parting and grooving / Introduction  2  3  1              Screws 1, 2 and 3 are used to clamp the module. Important:
                                                                Active insert clamping


                                                                clamp the module with screw 1, then screw 2. Afterwards the
                                                                insert is clamped by means of screw 3.
   611   612   613   614   615   616   617   618   619   620   621