Page 925 - Ceratizit Catalog
P. 925

Formula collection
                                                                                                                   D50










                                         vc · 1000
                                                           –1
              Revolution number      n =                [min ]     Material                Specific cutting
                                           π · D                                                      2
                                                                                           force k c  (N/mm )
                                          π · D · n
              Cutting speed          v  =               [m/min]
                                      c
                                           1000                    St 37.11; St 42.11      1740
                                                                   St 50.11                1950
              Feed rate              f                  [mm/rev.]
                                                                   St 60.11                2070
                                                                   St 70.11                2220
              Feed rate              v  =    f · n      [m/min]    C 35, C 45, Ck 45       2060/2175
                                      f
                                                                   C 60, Ck 60             2090
                                          π · D  2
              Machining cross section  A  =             [mm ]      16 Mn Cr 5              2060
                                                           2
                                      T
                                           4
                                                                   18 Cr Ni 6              2220
                                          vf · AT
                                                          3
              Metal removal rate     Q =                [cm /min]  34 Cr Mo 4              2190
                                          1000
                                                                   50 Cr V 4               2175
                                                            2
              Specific cutting force  k  = see table    [N/mm ]    tempered 100 Cr 6       2335
                                      c
                                                                   Mn, Cr Ni alloyed steel  2335
                                            Q
              Power requirements     P  =                        · k c  [kW]
                                      c
                                        60  · 1000 · η
                                                                   Cr Mo alloyed steel     2570
                                         f · kc  D 2
              Torque moment          M  =              ·  [Nm]
                                      c
                                         1000    8                 Corrosion resistant steel  2530
                                            D
              Feed force (approx.)   F   ≈  0,7         · f · k c  [N]  Hot working steel  2570
                                      f
                                            2
                                         L + h                     Nitriding steel         2570
              Drilling time          T  =               [min]
                                      c
                                          vf
                                                                   GS 45                   1570
              Clearance              h                  [mm]       GS 52                   1765
                                                                   GG 22, GG 25            1140
               Drilling depth        L                  [mm]       GGG 42                  1370
                                                                   Aluminium cast alloys   640
                                                                                  -values depend on the feed.
                                                                   Please note! The k c
                                                                   Therefore the table contains their upper limit
                                                                   values. The calculated power is possibly higher
                                                                   than the power actually needed (~ 10 - 20%).








                                                                                                                     Drilling / Technical information
   920   921   922   923   924   925   926   927   928   929   930