Control Cylinders
7250 psi maxThese unique pressure-indicating cylinders allow monitoring pressure on decoupled pallets. The plunger extends only while the set pressure is exceeded. Unlike other clamps and cylinders, Control Cylinders do not extend immediately under low pressure. Their internal springs are calibrated to restrict plunger movement until a set pressure is reached. Full plunger movement takes place entirely during a small "switching range" (hysteresis) during which the plunger moves from fully in to fully out. By using a probe or limit switch on the machine tool, you can check whether proper pressure is present or not.
Application Information
Limit switch mounted on machine table monitors clamping pressure by sensing the extended position of the Control Cylinder's plunger. If system pressure somehow drops below the set level, the plunger would retract.
Operation
The plunger extends only while the set pressure is exceeded. Unlike other clamps and cylinders, Control Cylinders do not extend immediately under low pressure. Their internal springs are calibrated to restrict plunger movement until a set pressure is reached. Full plunger movement takes place entirely during a small "switching range" (hysteresis) during which the plunger moves from fully in to fully out.
Pressure Setting
Select a Control Cylinder with a setting range based on desired system operating pressure. Usually Control Cylinders can be set approximately 20% under full operating pressure, unless tighter control is required. To set control pressure, turn front threaded bushing after loosening setscrew, then re-tighten setscrew.
Mounting & Fluid Supply
Fasten with two 1/4" or M6 socket-head cap screws. Dowel in place with two 6mm dowel pins. For manifold mounting, the mounting surface must be ground flat to ensure proper O-ring sealing. Drill 3/16" Diameter passage with a counterbore .531/.0535 Diameter x .057/.0061.1/4" BSPP port. Optional manifold-mounted version has an O-ring port underneath instead of a standard port. Do not use NPT fittings.
Parts Specification
Setting Range | Setting Range (PSI) | Switching Hysteresis (PSI) | Stroke (mm) |
Medium | 3200-5950 PSI | 440 PSI | 2.5mm |
Warning:
This product can expose you to materials and/or chemicals including arsenic, lead, and other materials and/or chemicals which are known to the state of California to cause cancer and/or reproductive harm.
For more information, visit www.P65Warnings.ca.gov